CANTILEVER


Click on the bold text to visualize the picture.

The cantilever shelving is suitable for storing long items such as tubes, bars, axles, beams and metal sheets. It consists of columns on which arms are hooked which support the load unit or the materials directly; it is possible to produce continuous surfaces , and if necessary a canopy for outdoor use of the cantilever. The height and depth modularity means that the shelving can be adapted to any space according to any requirements. The product can be supplied in single-front or twin-front version, with galvanised or painted finish. The arms can be positioned simply and quickly with a pitch of 76 mm, thus permitting optimal utilisation of the space available. Armes can produce cantilever shelving for installation in seismic areas or for use in cold rooms, or for outdoor applications.

TECHNICAL SHEET AND ACCESSORIES
accessoriesshock absorbers, arm protections, load stops, frames for continuous surfaces, coil supports, canopy arms
available finishingPowder painting: columns and arms
shelf typeBlue (RAL 5010), yellow (RAL 1007), grey (RAL 7016)
column heightfrom 2.000 mm to 7.000 mm
column dimensionsfrom 210 mm x 102 mm to 500 mm x 260 mm
column thicknessfrom 2,5 mm to 6 mm
column load capacityup to 27,7 kN (2.770 kg)
arm lengthfrom 400 mm to 2.200 mm
arm load capacityup to 5,5 kN (550 kg) u.d.l
CANTILEVER


CALCULATION
The load capacities of the various parts of the structure take into account the weight of the structure itself and the effective load and are based on the hypothesis of a uniformly distributed load (u.d.l.). Calculation of the load capacity of the columns takes account of the relative working conditions, considering the number, position and lenght of the arms. These capacities are calculated with the aid of an expressly developed automatic code.

The tests carried out and the entire set of algorithms used for the procedure comply with the most authoritative framework of standards and recommendations applicable in Italy and on a European level, including:
• A.C.A.I. CISI Technical Norm for the heavy pallet racks type of 28/06/2002;
• UNI ENV 1993-1-1:1994 and UNI ENV 1993-1-3: 2000 (Eurocode 3 – Steel structures design);
• CNR-UNI 10011:1997 (Steel constructions: instructions for the calculation, the execution, the test and the maintenance);
• CNR 10022:1998 (Cold profiles: instructions for the use in the constructions);
• D.M. 09/01/1996 (Technical Norms for the calculation, the execution and the test of the normal, pre-compressed concrete structures and for the metal structures);
• F.E.M. (Fédération Européenne de la Manutention) recommendations 10-2-02.